QNZ-200A DC Contactor

Rated Load Current (A): 200 Rated Load Voltage (VDC): 48 Rated Insulation Voltage (VDC): 1500 Coil Control Voltage (V): DC12/24/48/72/144 Coil Operating Power Consumption (W): 8.4–9.6 (DC24V), 7.5–10 (DC48V) Coil Connection Method: Screw Terminals / External Lead Wire Electrical Life (Operations): 1 × 10⁴ Mechanical Life (Operations): 10 × 10⁴ Mounting Method: Straight Bracket / Bent Bracket Auxiliary Contacts: Null

  • Product Description

1. Application

The QNZ-A series DC contactors are designed for use in inverters, soft starters, or other similar DC-20 load applications, serving as bypass isolation switches.

 Product Compliance Standards: IEC/EN 60947-4-1, GB/T 14048.4 

Product Certifications: CCC, CE, TUV, UL, RoHS

2. Coding

Q N Z –   A  

1  2   3  4  5 

Figures

Coding

1

Enterprise Code: QN represents Nanjing Quanning Electric Co., Ltd.

2

Z: DC Contactor

3

Basic Specification Code: the rated current (Ie)

4

A indicates normally open (NO) main contacts

5

Coil Voltage (Us)


3. Key Points

  • Compact size, lightweight, low power consumption, and high reliability.

  • High insulation performance, withstanding power frequency voltage of 3500V.

  • Coil terminals offer two connection options: fixed screw terminals or flexible lead wires.

  • Silver alloy contacts ensure reliable connection and low contact temperature rise.

  • Utilizes a single-coil structure.

  • Capable of handling 5 times overload (5Ie for 10 seconds).

  • Contacts, coil, and magnet are sealed within the housing, preventing dust ingress and allowing use in harsh environments.

  • Complies with the EU RoHS environmental directive and national energy-saving and environmental protection requirements.

4. Operating and Installation Conditions

  • Ambient Temperature: -40°C to +85°C.

  • Ambient Humidity: Maximum relative humidity of 85%.

  • Altitude: For installation altitudes exceeding 2000 meters, derate by 5% for every 1000-meter increase. Maximum allowable altitude is 5000 meters.

  • Vibration: Sinusoidal sweep vibration at the mounting point: 5–150Hz (Amplitude: 25/f for 5–20Hz; 250/f² for 20–150Hz).

  • Shock Acceleration: 30 m/s².

  • Pollution Degree: Degree 3.

  • Mounting Orientation: Horizontal or vertical.

  • Mounting Method: Screw mounting.

  • Applicable Duty Types: Uninterrupted duty and intermittent periodic duty.

5. Technical Parameters

This product series complies with the standards: IEC/EN 60947-4-1, GB/T 14048.4.

Specifications

Parameters

QNZ-200A

Number of Contacts

1P(Normally Open

Rated Insulation Voltage Ui(V)

1500

Rated Insulation Voltage Ui(VDC)

1500

Rated Operational Voltage Ue(VDC)

48

Rated Operational Current Ie(A)DC-1

200

Contact Voltage Drop Ud(mV)

≤85

Pole Impedance Z(mΩ)

≤0.4

Minimum Load for Make

24V  200mA

Coil

Coil Voltage Us(VDC)

24、48

Pick-up Voltage(VDC)

0.85Us~1.10Us

Drop-out Voltage(VDC)

0.10Us~0.75Us

Holding Current(A)

0.35~0.4(DC24V)、0.16~0.21(DC48V)

Holding Current(W)

8.4~9.6(DC24V)、7.5~10(DC48V)

Electrical  

      Life

DC-1,Ue,Ie

  (x10^4 operations)

1

Operating Frequency(operations/hour)

1200

Mechanical Life (x10^4 operations)

10

Overload Performance(A)

1.5Ie/30min;3Ie/1min;5Ie/10s;8Ie/1s;

Operating   Times

Pick-up Time(ms)

20~40

Release Time(ms)

5~15

Main Contact Wire or Busbar Cross-section(mm2

95

Main Contact Terminal Tightening Torque (N.m)

M8 Bolt:6.0~9.0

Insulation Resistance (MΩ)

≥30(1500VDC)

Dielectric    Strength

Between coil and contacts

3500V AC, 1 Min, No breakdown or flashover, leakage current ≤5mA

Between open contacts

3500V AC, 1 Min, No breakdown or flashover, leakage current ≤5mA

Temperature Rise

Coil (at Us)

≤85K

Terminals (at Ie)

≤65K

Enclosure

<60K

Magnet     Wire

Temperature Resistance

≤180℃

Insulation Class

Class H

Withstand Voltage

(Wire to ground)

1000V AC/1Min, No breakdown or flashover, leakage current ≤5mA

Weight (kg)

Approx. 0.45


6. Outline and Installation Dimensions


1760579966387155.png1760580051652623.png

QNZ-200A Bent Bracket, Lead Wire


1760580191642002.png1760580150840492.png

QNZ-200A Bent Bracket, Screw Terminals


1760580246288149.png1760580246508227.png

QNZ-200A Bent Bracket, Screw Terminals + Insulating Barrier


1760580314843388.png1760580314988587.png

QNZ-200A Straight Bracket, Lead Wire


1760580376752435.png1760580377989720.png

QNZ-200A Straight Bracket, Screw Terminals


1760580491654116.png1760580492265614.png

QNZ-200A Straight Bracket, Screw Terminals + Insulating Barrier

7. Connection Diagram

1760580866419751.png           1760580867749754.png

QNZ-A Series(without magnetic blowout)    QNZ-A Series(with magnetic blowout)


8. Ordering Information

 When placing an order, please specify: 

■ Contactor model and name; 

■ Coil voltage; 

■ Order quantity; 

■ Special requirements;

Q N Z –   A  

1  2   3  4  5 

Figures

Coding

1

Enterprise Code: QN represents Nanjing Quanning Electric Co., Ltd.

2

Z: DC Contactor

3

Basic Specification Code: the rated current (Ie)

4

A indicates normally open (NO) main contacts

5

Coil Voltage (Us)

Examples:

QNZ-200A DC24V Bent Bracket, Screw Terminals 100 units;
100 units DC contactor, one normally open main contact, 200A current, bent bracket mounting, screw terminals, coil voltage DC24V.

QNZ-400A DC48V Straight Bracket, Lead Wire 500mm 100 units;
100 units DC contactor, one normally open main contact, 400A current, straight bracket mounting, 500mm lead wire, coil voltage DC48V.
 

9. Precautions for Use

◆ The product coil is non-polarized. The main circuit with magnetic blowout is polarized (L1 is positive, L2 is negative); without magnetic blowout, it is non-polarized. The positive and negative terminals must not be reversed, as reversal can affect the load-breaking life.

◆ When using more than one connection wire at the power terminal, ensure the main power conductor is closest to the contactor's main circuit connection point, with smaller current wires on top, followed by the washer, spring washer, and nut. Incorrect connection order or loose connections can cause severe overheating and melt the cable insulation.


1764743581274140.jpg

◆ The tightening torque for screws and bolts used with the contactor should be controlled within the specified ranges below (see table).

M3 Screw: 0.5~0.8 N.m

M3.5 Screw: 0.8~1.2 N.m

M4 Screw: 1.2~1.8 N.m

M5 Screw: 2.0~3.0 N.m

M6 Bolt: 3.0~4.5 N.m

M8 Bolt: 6.0~9.0 N.m

M10 Bolt: 10.0~15.0 N.m

M12 Bolt: 14.0~21.0 N.m


◆ Main contact wire or busbar cross-sectional area (see table).

50 Amps: 10mm²

100 Amps: 35mm²

200 Amps: 95mm²

300 Amps: 185mm²

400 Amps: 240mm²

500 Amps: 300mm²

600 Amps: 400mm²

800 Amps: 500mm²


◆ Prohibit forcibly bending the wire or busbar after installing and tightening the screws, to prevent damage to the contactor and ensure its normal operation!