文章
  • 文章
Search

语言/language

Product Detail

QNZ1-160QR Built-in Resistor Micro-power DC Contactor (Aux. Contacts Opt.)

Rated operational current (A): 160

Rated operational voltage (V DC): 60 Rated insulation voltage (V DC): 1500 Coil control voltage (V): DC24/48 Coil operating power consumption (W): 0.5 Coil connection method: Terminal pin / External lead Electrical life (operations): 2×10⁴ Mechanical life (operations): 20×10⁴ Mounting method: Straight plate / Bent plate Auxiliary contacts: Optional (11/20/02)

  • Product Description

1. Application

The QNZ1-QR series DC contactors with built-in resistor and micro-power consumption are used as bypass isolation switches in variable frequency drives, soft starters, high-frequency heating power supplies, or other similar DC-20 loads. They can also be used in circuits with a working voltage of 60V or below under DC-1 load conditions.

Compliance Standards: IEC/EN 60947-4-1, GB/T 14048.4.
Product Certifications: CCC, CE, TUV, UL, RoHS.

2.Coding

image.png

Figures

Coding

1

Enterprise Code. QN represents Nanjing Quanning Electric Co., Ltd.

2

Z: DC Contactor

3

1: Product series

4

Basic Specification Code,  the rated current Ie

5

Q indicates micro-power consumption type.

6

Model Code. Default: None, indicates standard model. X indicates X-type model.

7

Contact Configuration. Default: None, indicates one normally open main contact. B indicates one normally

closed main contact.

8

Auxiliary Contacts. Default: None. Can be added: F11 (one NO, one NC), F20 (two NO), F02 (two NC).

9

Coil Voltage Us

10

Product Code. Default: R. RR indicates with built-in buffer resistor.

3. Key Points

▲ Built-in buffer resistor structure eliminates the need for installing additional charging resistors, saving customer cost while maintaining virtually the same space and volume. ▲ Coil with micro-power consumption technology, featuring high efficiency, energy saving, and surge protection. The coil itself does not generate heat. ▲ Strong resistance to shock and vibration. High contact pressure, silver alloy contacts ensure reliable connection, low contact temperature rise, and strong overload capacity. ▲ Rare earth strong magnetic arc extinguishing, long electrical lifespan, strong anti-welding performance, safe and reliable. ▲ High insulation performance, withstands 3500V power frequency voltage. ▲ Complies with EU RoHS environmental directive and national energy-saving and environmental protection requirements. ▲ Two coil connection options: Fixed terminal block method and flexible lead wire method. *(Note: 600-1200QR models are only available with lead wires).

4. Operating and Installation Conditions

▲ Ambient Temperature: -40°C to +85°C. ▲ Ambient Humidity: Maximum relative humidity 85%. ▲ When the installation site altitude exceeds 2000 meters, derate by 5% for every additional 1000 meters. Maximum altitude should not exceed 5000 meters. ▲ Sinusoidal sweep frequency vibration at the mounting point: 10–500 Hz (Frequency 10–50 Hz, Amplitude 2.5mm; 50–200 Hz, Amplitude 0.16mm; 200–500 Hz, Acceleration 50 m/s²). ▲ Pollution Degree: Pollution Degree 3. ▲ Installation Orientation: Horizontal or vertical. ▲ Mounting Method: Screw mounting. ▲ Applicable Duty Cycle: Uninterrupted duty, Intermittent periodic duty.

5. Technical Parameters

This series complies with standards: IEC/EN 60947-4-1, GB/T 14048.4.

Specifications

Parameters

QNZ1-160QR

Contact Configuration

1P (NO or NC); 1P (NO or NC) + F11, F20, F02

Rated Insulation Voltage Ui (V)

1500

Bypass Operating Voltage Un (VDC)

1500

Rated Operational Voltage Ue (VDC)

60

Rated Operational Current Ie (A) DC-1

160

Contact Voltage Drop Ud (mV)

≤60

Polar Impedance Z (mΩ)

≤0.4

Min. Connectable Load

24V  200mA

Auxiliary Contact Parameters

Ith: 10A; DC-12: Ue/Ie: 24V/10A; DC-12: Ue/Ie: 48V/4A; DC-12: Ue/Ie: 220V/1A.

Control Coil

Coil Voltage Us (VDC)

24、48

Pick-up Voltage (VDC)

0.85Us~1.10Us

Drop-out Voltage (VDC)

0.10Us~0.75Us

Pick-up Current (A)

<3

Holding Current (A)

<0.05

Pick-up Power (W)

<90

Holding Power (W)

<0.5

Recommended Power Supply

Switching power supply; PWM modulated power supply with 100% duty cycle; Rectifier-filtered power supply with ripple factor <5%

Optional Power Supply

(Customized)

DC square wave power supply; Rectifier-filtered power supply with ripple factor >5%

Electrical Life

DC-1, Ue, Ie (10k operations)

2

Operating Frequency (operations/hour)

300 (1 operation every 12 seconds, on/off interval not less than 2s)

Mechanical Life (10k operations)

20

Overload Performance (A)

1.5Ie/30min;3Ie/1min;5Ie/10s;8Ie/1s

Operate Time

Pick-up Time (ms)

600

Drop-out Time (ms)

50

Main Contact Wire or Busbar Cross-sectional Area

(mm²)

70

Main Contact Terminal Tightening Torque (N.m)

M6 bolt: 3.0–4.5

Insulation Resistance (MΩ)

≥5 (500VDC)

Dielectric Strength

Between Coil and Contacts

AC 3500V/1Min, no breakdown or flashover, leakage current ≤5mA

Between Open Contacts

AC 3500V/1Min, no breakdown or flashover, leakage current ≤5mA

Temperature Rise

Coil (at Us)

≤15K

Terminal (at Ie)

≤65K

Housing

<60K

Enameled Wire

Temperature Resistance

≤180℃

Insulation Class

Class H

Dielectric Strength

(Enamel to Ground)

AC 1000V/1Min, no breakdown or flashover, leakage current ≤5mA

Weight (kg)

Approx. 0.15

 

Appendix: Coil Parameters

Coil Voltage (VDC)

Starting Current (A)

Holding Current (A)

Pick-up Power (W)

Holding Power (W)

24

≤1.5

≤0.02

≤36

≤0.48

48

≤1

≤0.01

≤48

≤0.48

6. Outline and Mounting Dimensions (Same for NO and NC Types)

image.pngimage.pngimage.pngimage.png   

160QR                                           160QR                                                  160QR                                                 160QR

Bent Plate - Terminal Block                  Bent Plate - Lead Wire                          Straight Plate - Terminal Block            Straight Plate - Lead Wire

 

image.pngimage.png

160QR                                                   160QR

 No Plate - Terminal Block                         No Plate - Lead Wire


1761015466564573.png

QNZ1- 160QR Bent Plate Terminal Block Outline and Mounting Dimensions


1761015516303997.png


QNZ1- 160QR Bent Plate Lead Wire Outline and Mounting Dimensions


1761015550945971.png


QNZ1-160QR  Straight Plate Terminal Block Outline and Mounting Dimensions


1761015600288252.png


QNZ1- 160QR Straight Plate Lead Wire Outline and Mounting Dimensions


1761015657469322.png


QNZ1- 160QR No Plate Terminal Block Outline and Mounting Dimensions


1761015690113816.png


QNZ1- 160QR No Plate Lead Wire Outline and Mounting Dimensions

7. Wiring Diagram (Positive and Negative Poles Must NOT Be Reversed)

1761018078652824.png

QNZ1-QR                   QNZ1-QRR

8. Ordering Information

When placing an order, please specify:        ■ Contactor model and name;        ■ Coil voltage;        ■ Order quantity;        ■ Special requirements; 


image.png

Figures

Coding

1

Enterprise Code. QN represents Nanjing Quanning Electric Co., Ltd.

2

Z: DC Contactor

3

1: Product series

4

Basic Specification Code,  the rated current Ie

5

Q indicates micro-power consumption type.

6

Model Code. Default: None, indicates standard model. X indicates X-type model.

7

Contact Configuration. Default: None, indicates one normally open main contact. B indicates one normally

closed main contact.

8

Auxiliary Contacts. Default: None. Can be added: F11 (one NO, one NC), F20 (two NO), F02 (two NC).

9

Coil Voltage Us

10

Product Code. Default: R. RR indicates with built-in buffer resistor.

Examples:QNZ1-200QRR DC24V Bent Plate Lead Wire 100 units; Meaning: 100 units of DC contactor with built-in buffer resistor and micro-power consumption, current 200A, with resistor, with bent mounting plate, with lead wires, coil voltage DC24V. QNZ1-400QR DC48V Straight Plate Terminal Block 100 units; Meaning: 100 units of DC contactor with micro-power consumption, without resistor, with straight mounting plate, with terminal blocks, current 400A, coil voltage DC48V. QNZ1-600QXR DC48V No Plate Terminal Block 100 units; Meaning: 100 units of DC contactor with micro-power consumption, X-type, without resistor, without mounting plate, with terminal blocks, current 600A, coil voltage DC48V.

9. Usage Precautions

WARNING:     ◆ The product coil is polarized. If connected in reverse, the contactor will not operate. The main circuit with magnetic blowout is polarized (L1 is positive, L2 is negative); without magnetic blowout, it is non-polarized. The positive and negative poles must NOT be reversed, as reversal can affect the load-breaking lifespan.     ◆ The energy-saving coil has a relatively large starting current at initial operation, lasting between 100–120ms depending on the product's characteristics. Therefore, the driving power for the contactor must be greater than the coil power, and the operating frequency must not exceed the rated value. Otherwise, it may affect the normal starting of the DC contactor or even burn out the energy-saving module, rendering the contactor inoperative.     ◆ The product has a built-in coil energy-saving module; no additional PWM or other energy-saving modules are required. If PWM pulse signals are still used to control the coil, the PWM output voltage must be set to 100%, otherwise it may affect the reliable operation of our contactors. Step-type power supply mode is recommended.     ◆ When using more than one connection wire at a power terminal, ensure the main power wire is closest to the contactor's main circuit connection point, followed by smaller current wires on top, then the washer, spring washer, and nut. Incorrect connection order or loose connections can cause severe overheating and melt the cable insulation.

1764743581274140.jpg

   

    ◆ The tightening torque for screws and bolts used with the contactor should be controlled within the specified ranges below .

M3 Screw: 0.5~0.8 N.m

M3.5 Screw: 0.8~1.2 N.m

M4 Screw: 1.2~1.8 N.m

M5 Screw: 2.0~3.0 N.m

M6 Bolt: 3.0~4.5 N.m

M8 Bolt: 6.0~9.0 N.m

M10 Bolt: 10.0~15.0 N.m

M12 Bolt: 14.0~21.0 N.m


    ◆ Main contact wire or busbar cross-sectional area .

50 Amps: 10mm²

100 Amps: 35mm²

160 Amps: 70mm²

200 Amps: 95mm²

300 Amps: 185mm²

400 Amps: 240mm²

500 Amps: 300mm²

600 Amps: 400mm²

800 Amps: 500mm²

1000 Amps: 600mm²

1200 Amps: 800mm²


    ◆ Do NOT forcibly bend wires or busbars after tightening the product's mounting screws, to prevent damage to the contactor and ensure its normal use.



This site already supports IPv6
×
seo seo