QNJ-100C Zero-Power Magnetic Latching DC RelayRated operational current (A): 100 Rated operational voltage (V DC): 60 Rated insulation voltage (V DC): 1500 Coil control voltage (V): DC12/24 Coil operating power consumption (W): 0 Coil connection method: Plug-in Electrical life (operations): 1×10⁴ Mechanical life (operations): 20×10⁴ Auxiliary contacts: Null
1. ApplicationThe QNJ-C series zero-power magnetic latching DC relays are mainly used in energy storage,charging equipment, etc. Product complies with standards: IEC/EN 60947-4-1, GB/T 14048.4. Product certification: RoHS. 2.CodingQN J – □ C □ 1 2 3 4 5
3.Key Points▲ Zero-power bistable magnetic latching energy-saving coil, with no self-heating of the coil;▲ High insulation performance, withstand voltage 3500V AC at power frequency; ▲ Complies with EU RoHS environmental directive and national energy-saving and environmental protection requirements. 4. Operating and Mounting Conditions▲ Ambient temperature: -40°C to +85°C; ▲ Ambient humidity: Maximum relative humidity 85%; ▲ For installations above 2000m altitude, derate by 5% per 1000m increment, maximum altitude not exceeding 5000m; ▲ Sinusoidal sweep vibration frequency at mounting point: 10 ~ 500Hz (Frequency 10Hz~50Hz, amplitude 2.5mm; 50Hz~200Hz, amplitude 0.16mm; 200Hz~500Hz, acceleration 50 m/s²); ▲ Shock acceleration: 300 m/s²; ▲ Pollution degree: Degree 3; ▲ Applicable duty types: Uninterrupted duty, intermittent periodic duty. 5. Technical ParametersThis product series complies with standards: IEC/EN 60947-4-1, GB/T 14048.4.
6. Outline and Mounting Dimensions
QNJ-100C Outline and Mounting Dimensions 7. Wiring Diagram
QNJ-C 8. Ordering InformationPlease specify the following when ordering: ■ Relay model and name; ■ Coil voltage; ■ Order quantity; ■ Special requirements. QN J – □ C □ 1 2 3 4 5
Example: QNJ-200C DC24V, 100 units; This indicates 100 units of zero-power magnetic latching DC relay, main contact 1NO, current 200A, coil voltage DC24V. 9. Usage Precautions◆ The relay coil is polarized (A1 is positive, A2 is negative); the main circuit is non-polarized. ◆ The bistable magnetic latching energy-saving coil has a relatively high inrush current during the initial make/break operation, lasting between 50ms~120ms depending on the product's characteristics. Therefore, the driver power supply must exceed the coil power rating, and the operating frequency must not exceed the rated value. Otherwise, it may affect the normal startup of the DC relay 'or' even burn out the coil, rendering the relay inoperable. ◆ The magnetic latching DC relay uses a square wave pulse power supply mode. The magnetic latching coil must not be continuously energized. Make: Connect coil A1 'or' red wire to positive, A2 'or' black wire to negative. Break: Connect coil A1 'or' red wire to negative, A2 'or' black wire to positive. ◆ Main contact wire 'or' busbar cross-section (see table below):
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||